How to design fire zones in commercial buildings

27.10.25

Designing fire zones in commercial buildings is a process that requires knowledge of the regulations, the right choice of materials and the ability to combine safety with a functional space. Modern office, retail and hotel buildings must meet strict fire standards while keeping an attractive, open interior. Planning the division of a building into zones properly ensures not only compliance with the regulations but also effective protection of people and property in the event of a fire.

Which regulations govern the design of fire zones?

In Poland, the basic document on fire safety is the Regulation of the Minister of Infrastructure of 12 April 2002 on the technical conditions for buildings and their location. It requires buildings to be divided into fire zones and structural elements of specified fire resistance to be used.

Designers must also follow PN-EN 13501-2, which defines the fire-resistance classes of building materials and elements. It introduces the REI designations, which stand for load-bearing capacity, integrity and insulation of the partition respectively.

How do fire zones differ in commercial buildings?

Commercial buildings have much larger areas and more intensive use than residential buildings. Offices, shopping centres and hotels host many people at the same time, which increases the risk in the event of a fire.

The regulations for commercial buildings are therefore stricter. Fire zones must be smaller and the separating partitions must have higher fire-resistance classes. Unlike single-family houses, commercial buildings require a precise division into zones.

How to determine the required fire-resistance class of partitions

The fire-resistance class of a partition depends on the type of building, its height and the use of the fire zone. In low-rise buildings REI 60 is often sufficient, while high-rise buildings use REI 120 or even REI 240.

The REI designation has three parameters. R stands for load-bearing capacity, E for integrity against flames and gases, and I for thermal insulation. The number indicates the time in minutes for which the partition must meet these requirements. An REI 60 fire-separating wall is commonly used in medium-sized office buildings.

Where in the building should fire partitions be placed?

Fire partitions should mark the boundaries between zones with different uses or with areas exceeding the permitted values. In office buildings, typical dividing lines are corridors, stairwells and technical areas.

A fire wall must stand on a foundation or floor slab with fire resistance no lower than the partition itself. Where it meets the external facade, it should project at least 30 cm. In retail buildings, partitions often separate warehouses from sales areas; in hotels, they separate circulation routes.

Can openings be designed in fire walls?

Openings in fire partitions are permitted, but under strict conditions. Door openings may not exceed 15% of the total wall area, and glazing a maximum of 10%.

All doors and glazing must be certified for the appropriate fire-resistance class. Only non-combustible or low-flammability materials may be used, and the right hardware and self-closing systems must also be provided.

Which materials work best in fire zones?

Fire partitions should be built from non-combustible materials classified A1 under PN-EN 13501-1. The most popular solutions are concrete and sand-lime blocks and special fire-certified glass systems.

Fire-resistant glass is a modern solution that combines safety with good looks. Glass systems rated EI30, EI60 or EI120 keep the interior transparent while dividing it into zones. The thickness of the partition also matters for its fire performance.

How to combine fire requirements with modern aesthetics

Designing fire zones in commercial buildings does not have to mean giving up light, transparent architecture. More and more investors choose glass systems that meet safety standards without closing off the space.

Glazed partitions allow visual continuity of the interior, which is particularly important in open-plan offices and hotel receptions. Certified fire systems are available in single- and double-glazed versions. A further advantage is interior acoustic walls that also act as fire partitions.

Why invest in certified partition systems?

Certified fire partition systems guarantee compliance with the regulations and the certainty that they will work as intended in a fire. Manufacturers of such solutions carry out fire tests and obtain approvals confirming the performance of their products.

Using proven systems also makes design and installation easier. Complete kits are available, including profiles, hardware, seals and installation instructions. For the investor, a certified system saves time during handover and comes with a warranty, which provides additional security for the investment.